Abaqus Volume II: I–Z Manual do Utilizador Página 291

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 628
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 290
*
POROUS FAILURE CRITERIA
16.19
*
POROUS FAILURE CRITERIA: Define porous material failure crit eria for a
*
POROUS
METAL PLASTICITY mo del.
This option is used to specify the material failure criteria in a porous metal.
Product: ABAQUS/Explicit
Type: Model data
Level: Model
References:
*
POROUS METAL PLASTICITY
“Porous metal plasticity,” Section 18.2.9 of the ABAQUS Analysis User ’s Manual
There are no parameters associated with this option.
Data line to define material failure criteria:
First (and only) line:
1. Void volume fracti on at total failure, . The default is 1.
2. Critical void volume fraction (threshold o f rapid loss of stress carrying capacity),
.The
default is
.
16.19–1
ABAQUS Version 6.1 Module:
ID:
Printed on:
Vista de página 290
1 2 ... 286 287 288 289 290 291 292 293 294 295 296 ... 627 628

Comentários a estes Manuais

Sem comentários