SOLUTION TECHNIQUE
Data line for TYPE=CONTACT ITERATIONS:
First (and only) line:
1. Correction factor on the maximum number of right-hand-side solutions during any co ntact
iteration. The default is 1. The actual number of allowed right-hand-side solutions with the
correction factor accounted for is printed in the message file if
*
PRINT, CO NTACT=YES is
specified.
2. Maximum number of contact iterations allowed before new global matr ix assemblage and
factorization. The default is 30.