Abaqus Volume II: I–Z Manual do Utilizador Página 597

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 628
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 596
*
USER OUTPUT VARIABLES
20.7
*
USER OUTPUT VARIABLES: Specify number of user variables.
This option is used to allow ABAQ US to allocate space at each material calculation point for user-defined
output variables defined in user subroutine UVARM.Ifthe
*
USER OUTPUT VARIABLES option is used, it
must appear within each of the relevant material or gasket behavior definitions.
Product: ABAQUS/Standard
Type: Model data
Level: Model
Reference:
“UVARM,” Section 1.1.44 of the ABAQUS User Subroutines Reference Manual
There are no parameters associated with this option.
Data line to specify the number of user variables:
First (and only) line:
1. Number of user-defined variables required at each m aterial point.
20.7–1
ABAQUS Version 6.1 Module:
ID:
Printed on:
Vista de página 596
1 2 ... 592 593 594 595 596 597 598 599 600 601 602 ... 627 628

Comentários a estes Manuais

Sem comentários